09000-02263 PUMP ASSY, INJECTI Denso Cross


 

Information pump assy, injecti

09000-02263 PUMP ASSY, INJECTI
Rating:
52
Buy PUMP ASSY, INJECTI 09000-02263 genuine, new aftermarket engine parts with delivery

Components :

001. PUMP ASSY, INJECTI 09000-02263
002. BODY ASSY, INJECTI 09010-01012
003. PUMP ASSY, FUEL FE 09210-00671
004. COUPLING ASSY 09250-00291

Scheme ###:

000. [01] 09000-02263 PUMP ASSY, INJECTI
006. [01] 09010-01012 BODY ASSY, INJECTI
007. [01] 09080-00721 GOVERNOR ASSY, MEC
008. [06] 94900-50191 SCREW, SLOTTED FLA 94900-50190
009. [01] 91518-08221 BOLT, W/WASHER 91518-08221
010. [01] 09210-00671 PUMP ASSY, FUEL FE
011. [01] 09250-00291 COUPLING ASSY 61107-32600
012. [01] 09001-80010 COVER, CONTROL RAC 09001-80010
013. [01] 09001-20010 NUT, TIMER ROUND
014. [01] 90258-12001 WASHER, SPRING 90258-12001
015. [01] 94913-00050 KEY, WOODRUFF 94913-00050
016. [01] 09006-10011 COVER, PRIMING PUM 09006-10011

Include in #3:

09000-02263 as PUMP ASSY, INJECTI

Cross reference number



Part num Firm num Firm Name
09000-02263    PUMP ASSY, INJECTI




Information:

Disassembly of Water Pump
Inspection of Water Pump
If the inspection of the impeller and shaft finds abnormal noise or rough rotation, replace the assembly.
Inspection of impeller and shaft rotation conditionThermostat
Disassembly of Thermostat
Inspection of Thermostat
To test the thermostat operation, immerse the thermostat in a container filled with water, and heat the water while measuring the water temperature. Record the temperature at which the valve starts to open and the temperature at which the valve lift becomes 8 mm [0.3 in.] or more. (a) Stir the water in the container to ensure uniform temperature distribution.(b) When installing the thermostat, be sure to check the valve opening temperature indication stamped on the upper face of the thermostat mounting flange.
Inspection of thermostatThermo Switch
Inspection of Thermo Switch
Immerse the temperature sensor in oil, and measure the resistance while increasing the oil temperature. If the temperature measurement exceeds the standard value significantly, replace the thermo switch.
Since the inspection requires heating of oil to high temperatures, be careful not to get burns or start a fire.
Inspection of thermo switch