Information delivery- valve holder
BOSCH
9 411 613 748
9411613748
ZEXEL
134171-0200
1341710200
MITSUBISHI
ME723546
me723546
Rating:
Include in ###:
Cross reference number
Zexel num
Bosch num
Firm num
Name
134171-0200
9 411 613 748
ME723546 MITSUBISHI
DELIVERY- VALVE HOLDER
C 14GV HOLDER;D.V. Others
C 14GV HOLDER;D.V. Others
Information:
Water Pump
Inspection of Water Pump
If the inspection of the impeller and shaft finds abnormal noise or rough rotation, replace the assembly.
Inspection of impeller and shaft rotation conditionThermostat
Disassembly of Thermostat
Inspection of Thermostat
To test the thermostat operation, immerse the thermostat in a container filled with water, and heat the water while measuring the water temperature. Record the temperature at which the valve starts to open and the temperature at which the valve lift becomes 8 mm [0.3 in.] or more. (a) Stir the water in the container to ensure uniform temperature distribution.(b) When installing the thermostat, be sure to check the valve opening temperature indication stamped on the upper face of the thermostat mounting flange.
Inspection of thermostatOverheat Warning Unit (Thermo Switch)
Inspection of Overheat Warning Unit
Immerse the temperature sensor in oil, and measure the resistance while increasing the oil temperature. If the temperature measurement exceeds the standard value significantly, replace the thermo switch.
Since the inspection requires heating of oil to high temperatures, be careful not to get burns or start a fire.
Overheat warning unit
Inspection of Water Pump
If the inspection of the impeller and shaft finds abnormal noise or rough rotation, replace the assembly.
Inspection of impeller and shaft rotation conditionThermostat
Disassembly of Thermostat
Inspection of Thermostat
To test the thermostat operation, immerse the thermostat in a container filled with water, and heat the water while measuring the water temperature. Record the temperature at which the valve starts to open and the temperature at which the valve lift becomes 8 mm [0.3 in.] or more. (a) Stir the water in the container to ensure uniform temperature distribution.(b) When installing the thermostat, be sure to check the valve opening temperature indication stamped on the upper face of the thermostat mounting flange.
Inspection of thermostatOverheat Warning Unit (Thermo Switch)
Inspection of Overheat Warning Unit
Immerse the temperature sensor in oil, and measure the resistance while increasing the oil temperature. If the temperature measurement exceeds the standard value significantly, replace the thermo switch.
Since the inspection requires heating of oil to high temperatures, be careful not to get burns or start a fire.
Overheat warning unit
Have questions with 134171-0200?
Group cross 134171-0200 ZEXEL
Mitsubishi
134171-0200
9 411 613 748
ME723546
DELIVERY- VALVE HOLDER