Buy 131116-4900 ZEXEL 9 411 610 300 BOSCH DELIVERY- VALVE HOLDER 9411610300 1311164900 me704011


 

Information delivery- valve holder

BOSCH 9 411 610 300 9411610300
ZEXEL 131116-4900 1311164900
MITSUBISHI ME704011 me704011
131116-4900 DELIVERY- VALVE HOLDER
Rating:
77
Buy DELIVERY- VALVE HOLDER 131116-4900 zexel genuine, new aftermarket engine parts with delivery

Compare Prices: .

As an associate, we earn commssions on qualifying purchases through the links below
$32.97
 

12 Oct 2022
4.0[1.80] Pounds
US: Wheels Depot
Front Dynamic Friction Company 3000 Semi-Met Brake Pads 1311-1649-00
Dynamic Friction Company Designed to deliver trouble-free, consistent performance || Right for your vehicle and lifestyle || Made from high-quality materials for ultimate durability || Manufactured to meet or exceed strict quality requirements || If you have any questions or need fitment information for your vehicle, please contact with us

Cross reference number

Zexel num
Bosch num
Firm num
Name
131116-4900 
9 411 610 300 
ME704011  MITSUBISHI
DELIVERY- VALVE HOLDER
C 14FL HOLDER;D.V. parts(A,AD) Others
131116-4900 
9 411 610 300 
EZ40060XX017  M.BISHI-HI.-NAG
DELIVERY- VALVE HOLDER
C 14FL HOLDER;D.V. parts(A,AD) Others




Information:

Water Pump
Disassembly of Water Pump
Inspection of Water Pump
If the inspection of the impeller and shaft finds abnormal noise or rough rotation, replace the assembly.
Inspection of impeller and shaft rotation conditionThermostat
Disassembly of Thermostat
Inspection of Thermostat
To test the thermostat operation, immerse the thermostat in a container filled with water, and heat the water while measuring the water temperature. Record the temperature at which the valve starts to open and the temperature at which the valve lift becomes 8 mm [0.3 in.] or more. (a) Stir the water in the container to ensure uniform temperature distribution.(b) When installing the thermostat, be sure to check the valve opening temperature indication stamped on the upper face of the thermostat mounting flange.
Inspection of thermostatThermo Switch
Inspection of Thermo Switch
Immerse the temperature sensor in oil, and measure the resistance while increasing the oil temperature. If the temperature measurement exceeds the standard value significantly, replace the thermo switch.
Since the inspection requires heating of oil to high temperatures, be careful not to get burns or start a fire.
Inspection of thermo switch

Have questions with 131116-4900?





Group cross 131116-4900 ZEXEL

Mitsubishi 

131116-4900  
9 411 610 300 
ME704011 
DELIVERY- VALVE HOLDER

M.Bishi-Hi.-Nag 

131116-4900  
9 411 610 300 
EZ40060XX017 
DELIVERY- VALVE HOLDER
Back to top