146615-5900 ZEXEL 9 461 628 078 BOSCH COUPLING PLATE 9461628078 1466155900 8973794750


 

Information coupling plate

BOSCH 9 461 628 078 9461628078
ZEXEL 146615-5900 1466155900
ISUZU 8973794750 8973794750
146615-5900 COUPLING PLATE
Rating:
78
Buy COUPLING PLATE 146615-5900 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 270/2
COUPLING PLATE
1047465620 as COUPLING PLATE

Cross reference number

Zexel num
Bosch num
Firm num
Name
146615-5900 
9 461 628 078 
8973794750  ISUZU
COUPLING PLATE
A C 11FV COUPLING parts(VE) Others




Information:


Always determine the cause of the engine shutdown. Make necessary repairs before attempting restarting the engine.
Air Shutoff Solenoid (If Equipped)
This optional solenoid is located on top of the engine in the air inlet system. When the solenoid is activated, the solenoid mechanically shuts off inlet air to the engine. The solenoid can only be activated by the overspeed switch or the emergency stop switch.Fuel Shutoff Solenoid
This solenoid is located on the governor or on the fuel injection pump. When the solenoid is activated, the solenoid moves the fuel rack (either directly or through the governor) to the Fuel Off position.Overspeed Shutoffs
Magnetic pickup (1), mounted in the flywheel housing (2).A magnetic pickup mounted in the flywheel housing senses the passage of the flywheel ring gear teeth. Should the engine speed increase above the overspeed setting of the Electronic Speed Switch (118 percent of rated engine speed), the magnetic pickup will sense the overspeed. The overspeed condition activates both the air (if equipped) and fuel shutoff solenoids.The shutoffs must be reset before the engine will restart. A reset button on the Electronic Speed Switch (in the junction box) must be pushed to open the overspeed switch. The air shutoff lever (at the top of the air inlet housing) must be manually reset.Oil Pressure Switches
Typical example of oil pressure switches, mounted in the rear of the junction box.An oil pressure switch has wires connected to the electrical system for alarm or shutoff functions. The oil pressure switch senses oil pressure at the bearing oil gallery. If sufficient oil pressure is not achieved after engine starting, or if the engine has been running normally and then loses oil pressure, the fuel shutoff solenoid is energized to shut the engine off. No resetting procedure is required.Engine Step Oil Pressure
This is an adjustable engine speed setting that protects the engine from a failure caused by too little oil pressure for a specified speed range. This option requires two different oil pressure switches. One switch has a high pressure rating- when the engine is running above the speed setting, the engine must maintain oil pressure higher than the switch rating. The other switch has a low pressure rating- an engine running below the speed setting must maintain oil pressure above the low switch rating.In an automatic start/stop system, an automatic reset switch is used. Manually operated systems require the switch to be reset before the engine will start.
If the RESET button does not move to the extended position after the engine starts, the engine will NOT be protected by this particular switch.If the RESET button remains in the reset position, the engine oil pump will not develop normal oil pressure. An inspection should be made to correct the problem.
In order to reset the switch, push the RESET button until the button latches. After the engine starts and develops oil pressure, the button will move to the extended (running) position.
The button must be in the RUN position to protect the engine. If the button remains in

Have questions with 146615-5900?





Group cross 146615-5900 ZEXEL

Isuzu 

146615-5900  
9 461 628 078 
8973794750 
COUPLING PLATE
9 461 628 079 
 
TOOTHED GEAR
Back to top