105662-1051 ZEXEL 9 423 618 266 BOSCH COUPLING PLATE 9423618266 1056621051 1157801131


 

Information coupling plate

BOSCH 9 423 618 266 9423618266
ZEXEL 105662-1051 1056621051
ISUZU 1157801131 1157801131
105662-1051 COUPLING PLATE
Rating:
66
Buy COUPLING PLATE 105662-1051 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 156631-3700 COUPLING PLATE
2. [2] 156634-0900 BLEEDER SCREW
3. [2] 156615-4900 PLAIN WASHER
4. [1] 156605-2320 PLATE
6. [2] 029200-8050 UNION NUT
7. [2] 156634-1500 BLEEDER SCREW
11. [1] 156609-9800 COUPLING
12. [2] 156634-1500 BLEEDER SCREW
16. [1] 156605-2320 PLATE
17. [2] 156634-1900 BLEEDER SCREW
20. [1] 156633-1200 BLEEDER SCREW

Include in #1:

101603-0502 as COUPLING PLATE

Cross reference number

Zexel num
Bosch num
Firm num
Name
105662-1051 
9 423 618 266 
1157801131  ISUZU
COUPLING PLATE
* K 14GT COUPLING COUP




Information:

Appendix
Configuration Information
Table 7
Over-Temp    
Inlet Over-Temperature Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output function     ON only during alarm    
    Assert Alarm     Above
650 °C (1202 °F)    
    Hysteresis    
20 °C (68 °F)    
    Upon Over Temperature extend alarm for 60 seconds    
Table 8
Over-Pres    
Over-Pressure Warning        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     ON only during alarm    
    Assert Alarm when the measured pressure exceeds 7" of Hg for 5% of the time during a 60 min measurement interval    
Over-Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 2    
    Output Function     Latched ON upon alarm    
    Assert alarm when the measured pressure exceeds 8" of Hg for 5% of the time during a 60 min measurement interval    
Table 9
TC-Fail (1)    
Open Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if measured temperature is above
1000 °C (1832 °F)    
Shorted Thermocouple Detect        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Output During Alarm     Output 1    
    Output Function     Latched ON upon alarm    
    Assert alarm if pressure is greater than 1" of Hg for 10 min and measured temperature does not exceed
120 °C (248 °F)    
( 1 ) Output selection applies to both open and shorted alarms
Table 10
Pressure Sensor Fail    
No Change Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Outputs During Alarm     Output 1    
    Output Function     Latched ON upon Alarm    
    Assert alarm if exhaust temperature is above
250 °C (482 °F) for 10 min and the pressure doesn't change by at least 0.25" of Hg    
Negative Pressure Alarm        
    Condition     Expected Value    
    Enable Alarm     Yes    
    Log Alarm Transitions     Yes    
    Active Output During Alarm     Output 1    
    Output Function     Latched ON during alarm    
    Assert Alarm if temperature is above
200 °C (392 °F) for 10 min and the pressure is less than −1" of

Have questions with 105662-1051?





Group cross 105662-1051 ZEXEL

Nissan-Diesel 

9 423 618 593 
1682097003 
COUPLING PLATE

Hino 

9 423 617 827 
226001490A 
COUPLING PLATE
9 423 617 827 
S226001490A 
COUPLING PLATE

Komatsu 

9 423 618 594 
6302713610 
COUPLING PLATE
 
 

9 423 618 822 
 
COUPLING PLATE

Isuzu 

 
1157801130 
COUPLING PLATE
105662-1051  
9 423 618 266 
1157801131 
COUPLING PLATE
9 423 618 043 
 
COUPLING PLATE
9 423 617 846 
 
COUPLING PLATE
9 423 618 042 
 
COUPLING PLATE
Back to top