146535-1420 ZEXEL 9 461 613 504 BOSCH CONTROL LEVER 9461613504 1465351420 8944260760


 

Information control lever

BOSCH 9 461 613 504 9461613504
ZEXEL 146535-1420 1465351420
ISUZU 8944260760 8944260760
146535-1420 CONTROL LEVER
Rating:
9
Buy CONTROL LEVER 146535-1420 zexel genuine, new aftermarket engine parts with delivery

Include in ###:

Number on scheme 72B
CONTROL LEVER
1047481680 as CONTROL LEVER
1047496331 as CONTROL LEVER '514'
1047496332 as CONTROL LEVER

Cross reference number

Zexel num
Bosch num
Firm num
Name
146535-1420 
9 461 613 504 
8944260760  ISUZU
CONTROL LEVER
C 11FV LEVER parts(VE) Others




Information:


Illustration 1 g01339995
Over Temperature Alarm
The Over Temperature alarm monitors the particulate filter temperature and the over temperature alarm produces an alarm if the temperature exceeds a configurable threshold. The operator is informed of an Over Temperature Alarm. The Over-Temperature Warning alarm is set to the "ON" state when the monitored temperature reaches or exceeds the Assert Alarm temperature value as configured by the user through the monitoring system. Pin 59 in the "ON" state will illuminate the optional Over-Temperature LED. Refer Systems Operation Troubleshooting, Testing and Adjusting, KENR6695-00, "Input Components".Through the CAT ET service tool, the users may configure the conditions to reset the Over-Temperature Warning alarm to "OFF" by choosing one of two methods:
The Over-Temperature Warning alarm will automatically be set to the "OFF" state when the monitored temperature drops below the Assert Alarm temperature value.
The Over-Temperature Warning alarm will stay latched in the "ON" state until cleared by the user through Cat ET.Over-Pressure Alarm
The Over-Pressure Alarm monitors the particulate filter pressure and annunciates an alarm if the pressure exeeds a configurable threshold. The operator should be informed of an Over-Pressure Alarm. There are two configurable Over-Pressure Alarm sets of conditions. By programming the two configurable Over-Pressure Alarm sets differently, one may be considered a Warning alarm and the other as a Critical alarm. The Warning alarm will be associated with Pin 60 (the optional Over-Pressure LED) and the Critical alarm will be associated with Pin 61 (the optional System Problem LED).
The Warning alarm is associated with the Over-Pressure LED.
The Critical alarm is associated with the System Problem LED.Refer Systems Operation Troubleshooting, Testing and Adjusting, KENR6695-00, "Input Components"Conditions To Set The Over-Pressure Alarm To The "ON" State
When the pressure exceeds the Pressure Threshold for the programmed percent of time (Duty Cycle) over the Time Interval, then the appropriate alarm (Over-Pressure or System Problem) is set to "ON". The pressure is sampled in 1 second intervals.Conditions To Set The Over-Pressure Alarm To The "OFF" State
The user may configure the conditions to reset the Over-Pressure alarms to "OFF" by choosing one of two methods:
The Over-Pressure alarm is set to the "OFF" state when the "ON" conditions are no longer met.
The Over-Pressure alarm will stay latched in the "ON" state until the Logged Event is cleared by the user through Cat ET.Configurable Parameters - The following parameters are configurable through the CAT ET service tool,
Particulate Trap Over-Pressure Warning Activation Time Percentage – Default is 10%
Particulate Trap Over-Pressure Warning Alarm Reset Configuration – Default is Manual
Particulate Trap Over-Pressure Critical Alarm Activation Time Percentage – Default is 10%Programmable Monitoring System
The purpose of the programmable monitoring system is to give the customers the ability to customize how the system reacts to possible engine damaging conditions. This feature reduces the number of custom personality modules, and part numbers, needed to meet widely varying customer needs. CAT ET can be used to view Programmable Monitoring System settings and customize the Programmable Monitoring System if allowed via security settings. Table 1 describes the programmable monitoring system. In

Have questions with 146535-1420?





Group cross 146535-1420 ZEXEL

Isuzu 

146535-1420  
9 461 613 504 
8944260760 
CONTROL LEVER
Back to top