Information compression spring
BOSCH
9 461 610 142
9461610142
ZEXEL
146302-0300
1463020300
ISUZU
8942291580
8942291580

Rating:
Include in ###:
Number on scheme 34
1047400010
as COMPRESSION SPRING
K=2.8
1047400060
as COMPRESSION SPRING
1047403541
as COMPRESSION SPRING
K=2.80KG/MM
1047403620
as COMPRESSION SPRING
K=2.8
1047404420
as COMPRESSION SPRING
K=2.80KG/MM
1047404430
as COMPRESSION SPRING
1047404460
as COMPRESSION SPRING
K=2.8
1047404530
as COMPRESSION SPRING
1047404550
as COMPRESSION SPRING
K=2.80KG/MM
1047404580
as COMPRESSION SPRING
K=2.8
1047404590
as COMPRESSION SPRING
1047404610
as COMPRESSION SPRING
K=2.80KG/MM
1047404672
as COMPRESSION SPRING
1047404692
as COMPRESSION SPRING
K=2.8
1047482240
as COMPRESSION SPRING
1047482330
as COMPRESSION SPRING
K=2.8
Cross reference number
Zexel num
Bosch num
Firm num
Name
9 461 610 142
16621R8800 NISSAN
COMPRESSION SPRING
* C 11FV parts(VE) Others
* C 11FV parts(VE) Others
9 461 610 142
16825W3300 NISSAN
COMPRESSION SPRING
A * C 11FV parts(VE) Others
A * C 11FV parts(VE) Others
9 461 610 142
1682523G00 NISSAN
COMPRESSION SPRING
B * C 11FV parts(VE) Others
B * C 11FV parts(VE) Others
9 461 610 142
16621R8800 NISSAN-DIESEL
COMPRESSION SPRING
* C 11FV parts(VE) Others
* C 11FV parts(VE) Others
9 461 610 142
1682523G00 NISSAN-DIESEL
COMPRESSION SPRING
A * C 11FV parts(VE) Others
A * C 11FV parts(VE) Others
Information:
Cat Data Logging and Alarm System (DLAS) 300
The Cat DPF system requires a Cat Data Logging and Alarm System (DLAS). The Cat DLAS measures and records exhaust temperature and backpressure. These parameters are essential in determining whether the application duty cycle is acceptable for the filter. There are also a series of alarms to help the user in case a problem occurs.Establishing an Ethernet Connection
Connect a laptop or other computer to the DLAS300 using an ethernet cable. The ethernet cable is also referred to as a LAN or network cable.
Verify that the green link light on the ethernet connector is on.
Wait for Windows to configure the network.
Start Internet Explorer, Firefox, Chrome or another web browser on the laptop.
Enter dlas300 or 169.254.1.1 into the address bar of the web browser. The web page should begin to display within a few seconds.
If the page cannot be found, or if a different web page is displayed, refer to network troubleshooting.To communicate with the DLAS300, the ethernet adapter on the laptop must be configured with an IP address on the 169.254.0.0/16 network. If the laptop is configured to use DHCP but cannot find a DHCP server, Windows will use Automatic Private IP Addressing (APIPA) to choose an IP address on the 169.254.0.0/16 network.An alternate solution is to configure the Internet Protocol (TCP/IP) Properties with a static IP address. To configure a static IP address, follow the steps below:
Open "Network Connections" from the control panel and change the settings of the ethernet connection. Ethernet connection is often called Local Area Connection.
From the "Properties" dialog box, select "Internet Protocol" (TCP/IP) and click "Properties".
The 169.254.2.1 address is a suggestion.
Any IP address other than 169.254.1.1 or the DLAS300 address can be used.web Browser Proxy Settings
The web browser may be configured with proxy settings that prevent accessing the DLAS300. To disable the proxy settings for Internet Explorer or other browsers, follow the steps below:
Open the "Internet Options" dialog box.
Open the dialog box from either the tools menu of Internet Explorer or from the control panel.
Select the "Connections" tab and click the "LAN settings" button.
On the "Local Area Network (LAN) Settings" dialog box, de-select everything.Downloading Data
The logged data can be copied to a USB flash drive or downloaded through the web interface. The resulting data file is in comma-separated value (CSV) format for easy import into Microsoft Excel or other data analysis software. The first two lines of the file contain the engine name, engine serial number, catalyst serial number, and initial performance test results.To copy the logged data to a USB flash drive, perform the following steps:
Insert the USB flash drive into the USB port on the front panel.
Press and release the front panel button.
Monitor the activity light on the USB flash drive. The transfer is complete when no activity is indicated for more than 5 seconds. If the USB flash drive does not have an activity light, wait at least 5 minutes to ensure that all data has been copied.
Remove the USB flash driveCopying may take
The Cat DPF system requires a Cat Data Logging and Alarm System (DLAS). The Cat DLAS measures and records exhaust temperature and backpressure. These parameters are essential in determining whether the application duty cycle is acceptable for the filter. There are also a series of alarms to help the user in case a problem occurs.Establishing an Ethernet Connection
Connect a laptop or other computer to the DLAS300 using an ethernet cable. The ethernet cable is also referred to as a LAN or network cable.
Verify that the green link light on the ethernet connector is on.
Wait for Windows to configure the network.
Start Internet Explorer, Firefox, Chrome or another web browser on the laptop.
Enter dlas300 or 169.254.1.1 into the address bar of the web browser. The web page should begin to display within a few seconds.
If the page cannot be found, or if a different web page is displayed, refer to network troubleshooting.To communicate with the DLAS300, the ethernet adapter on the laptop must be configured with an IP address on the 169.254.0.0/16 network. If the laptop is configured to use DHCP but cannot find a DHCP server, Windows will use Automatic Private IP Addressing (APIPA) to choose an IP address on the 169.254.0.0/16 network.An alternate solution is to configure the Internet Protocol (TCP/IP) Properties with a static IP address. To configure a static IP address, follow the steps below:
Open "Network Connections" from the control panel and change the settings of the ethernet connection. Ethernet connection is often called Local Area Connection.
From the "Properties" dialog box, select "Internet Protocol" (TCP/IP) and click "Properties".
The 169.254.2.1 address is a suggestion.
Any IP address other than 169.254.1.1 or the DLAS300 address can be used.web Browser Proxy Settings
The web browser may be configured with proxy settings that prevent accessing the DLAS300. To disable the proxy settings for Internet Explorer or other browsers, follow the steps below:
Open the "Internet Options" dialog box.
Open the dialog box from either the tools menu of Internet Explorer or from the control panel.
Select the "Connections" tab and click the "LAN settings" button.
On the "Local Area Network (LAN) Settings" dialog box, de-select everything.Downloading Data
The logged data can be copied to a USB flash drive or downloaded through the web interface. The resulting data file is in comma-separated value (CSV) format for easy import into Microsoft Excel or other data analysis software. The first two lines of the file contain the engine name, engine serial number, catalyst serial number, and initial performance test results.To copy the logged data to a USB flash drive, perform the following steps:
Insert the USB flash drive into the USB port on the front panel.
Press and release the front panel button.
Monitor the activity light on the USB flash drive. The transfer is complete when no activity is indicated for more than 5 seconds. If the USB flash drive does not have an activity light, wait at least 5 minutes to ensure that all data has been copied.
Remove the USB flash driveCopying may take