Information bleeder screw
BOSCH
9 442 610 582
9442610582
ZEXEL
020146-1640
0201461640
ISUZU
1835795240
1835795240

Rating:
Include in ###:
Number on scheme 403
1010418000
as BLEEDER SCREW
M6P1.0L16
1010418074
as BLEEDER SCREW
1010418110
as BLEEDER SCREW
M6P1.0L16
1059211565
as BLEEDER SCREW
1059211585
as BLEEDER SCREW
M6P1.0L16
1059211974
as BLEEDER SCREW
1059212931
as BLEEDER SCREW
M6P1.0L16
Cross reference number
Zexel num
Bosch num
Firm num
Name
020146-1640
9 442 610 582
1835795240 ISUZU
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
ME723942 MITSUBISHI
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
0836061626 NISSAN
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
1922089TA0 NISSAN
BLEEDER SCREW
A D 90HY BOLT Standard parts Others
A D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
19382S9400 NISSAN-DIESEL
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
907976616 MAZDA
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
SL0113614 MAZDA
BLEEDER SCREW
A D 90HY BOLT Standard parts Others
A D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
011706160 FUJI-HEAVY
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
19467090640 YANMAR
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
0360511 KUBOTA
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
020146-1640
9 442 610 582
1116006161 HYUNDAI
BLEEDER SCREW
D 90HY BOLT Standard parts Others
D 90HY BOLT Standard parts Others
Information:
Condition: DEF nozzle does not shut off, causing DEF to exit the tank breather
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at a downward angle may cause DEF to exit breather before the float in the tank valve rises enough to shut off nozzle.
Verify that the pressure at the nozzle from supply pump meets minimum 172 to 200 kPa (25 to 29 psi) requirement to trigger nozzle shut off.
Inspect tank-mounted valve for debris or ice preventing closure.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Replace or repair as needed.Condition: DEF Nozzle shuts off before tank is full
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at an upward angle may cause DEF Nozzle to shut off prematurely because DEF level at the rear of the tank near valve may cause float to rise and shut off nozzle.
Verify that flow at nozzle does not exceed the recommended target of 45 L/min (12 US gpm).
Excessive flow can damage tank-mounted valve and cause premature shut off.
Inspect vent line going up to breather and breather for any blockage, clean or replace if needed.
Inspect DEF fast fill line from receiver to valve, the valve for any blockages. Clean or replace if needed.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Repair or replace as needed.
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at a downward angle may cause DEF to exit breather before the float in the tank valve rises enough to shut off nozzle.
Verify that the pressure at the nozzle from supply pump meets minimum 172 to 200 kPa (25 to 29 psi) requirement to trigger nozzle shut off.
Inspect tank-mounted valve for debris or ice preventing closure.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Replace or repair as needed.Condition: DEF Nozzle shuts off before tank is full
Troubleshooting Steps:
Machine should be parked on level surface during DEF fill. Parking the machine with front end running at an upward angle may cause DEF Nozzle to shut off prematurely because DEF level at the rear of the tank near valve may cause float to rise and shut off nozzle.
Verify that flow at nozzle does not exceed the recommended target of 45 L/min (12 US gpm).
Excessive flow can damage tank-mounted valve and cause premature shut off.
Inspect vent line going up to breather and breather for any blockage, clean or replace if needed.
Inspect DEF fast fill line from receiver to valve, the valve for any blockages. Clean or replace if needed.
Inspect nozzle for damage from rough handling, DEF crystal buildup. Repair or replace as needed.
Have questions with 020146-1640?
Group cross 020146-1640 ZEXEL
Isuzu
020146-1640
9 442 610 582
1835795240
BLEEDER SCREW
Mitsubishi
020146-1640
9 442 610 582
ME723942
BLEEDER SCREW
Nissan
020146-1640
9 442 610 582
0836061626
BLEEDER SCREW
020146-1640
9 442 610 582
1922089TA0
BLEEDER SCREW
Nissan-Diesel
020146-1640
9 442 610 582
19382S9400
BLEEDER SCREW
Mazda
020146-1640
9 442 610 582
907976616
BLEEDER SCREW
020146-1640
9 442 610 582
SL0113614
BLEEDER SCREW
Fuji-Heavy
020146-1640
9 442 610 582
011706160
BLEEDER SCREW
Yanmar
020146-1640
9 442 610 582
19467090640
BLEEDER SCREW
Kubota
020146-1640
9 442 610 582
0360511
BLEEDER SCREW
Hyundai
020146-1640
9 442 610 582
1116006161
BLEEDER SCREW