105680-5100 ZEXEL 9 420 616 704 BOSCH AUTOM. ADVANCE MECHANISM 9420616704 1056805100 me755827


 

Information autom. advance mechanism

BOSCH 9 420 616 704 9420616704
ZEXEL 105680-5100 1056805100
MITSUBISHI ME755827 me755827
105680-5100 AUTOM. ADVANCE MECHANISM
Rating:
56
Buy AUTOM. ADVANCE MECHANISM 105680-5100 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 156800-5820 TIMING-DEVICE HOUSING
2. [1] 156801-3800 FLANGE BUSHING
3. [2] 156723-0300 ECCENTRIC DISC
3. [2] 156723-0300 ECCENTRIC DISC
4. [2] 156723-0400 ECCENTRIC DISC
4. [2] 156723-0400 ECCENTRIC DISC
5. [1] 156898-7220 FLYWEIGHT ASSEMBLY
5/1. [2] 156802-0520 FLYWEIGHT
5/1. [2] 156802-0520 FLYWEIGHT
5/2. [4] 156807-1100 SLOTTED WASHER
5/2. [4] 156807-1100 SLOTTED WASHER
5/3. [4] 156807-0900 SLOTTED WASHER
5/3. [4] 156807-0900 SLOTTED WASHER
5/4. [4] 156896-2600 COMPRESSION SPRING
5/4. [4] 156896-2600 COMPRESSION SPRING
5/6. [4] 156809-0300 LOCKING WASHER
5/6. [4] 156809-0300 LOCKING WASHER
5/7. [2] 156806-0900 PIN
5/8/1. [0] 156728-0800 SHIM D19&15T0.1
5/8/1. [0] 156728-0900 SHIM D19&15T0.3
5/8/1. [0] 156728-0900 SHIM D19&15T0.3
5/8/1. [0] 156728-1000 SHIM D19&15T0.5
5/8/1. [0] 156728-1100 SHIM D19&15T1.0
5/8/1. [0] 156728-2000 SHIM D19&15T0.4
5/8/1. [0] 156728-2100 SHIM D19&15T0.7
5/10. [4] 156808-0500 SPACER BUSHING
13. [1] 156809-1520 COVER
13/2. [1] 139648-0300 PACKING RING
13/3. [1] 156315-0200 O-RING
30. [1] 156729-1400 LOCKING WASHER
31. [1] 131325-1800 UNION NUT
33. [1] 029331-0190 GASKET D14&10.2T1
34. [1] 156316-0000 CAPSULE
35. [1] 156314-0600 CAP
36. [1] 156319-0200 GASKET

Include in #1:

101608-6460 as AUTOM. ADVANCE MECHANIS

Cross reference number

Zexel num
Bosch num
Firm num
Name
105680-5100 
9 420 616 704 
NP-EP/SPG550-650B3DL 
ME755827  MITSUBISHI
AUTOM. ADVANCE MECHANISM
K 14KL AUTOMATIC TIMER TIMER SPG TIMER




Information:

password protection for the CCM is initially enabled. Password protection may be necessary for some applications. Use the following procedure to enable password protection. Changing the password protection can be done with the PC software for the CCM . The password protection can also be changed by using a host device to write the IIDs.Disabling PasswordsTo disable the passwords, the AA12 and AA8A PIDs must be used.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA8A with the level 3 password. This will set the security level in the CCM to level 3. The message will be 5000340C0061AA8Ab1b2b3b4b5b6b7b8cs. The example above shows that b1 through b8 are the ASCII characters of the password. If the password is all spaces, simply end the message after PID AA8A. Do not include any of the data bytes. The CCM will automatically add spaces when a character is not present.
Use IID 34 with a unit number of 61. Write PID AA 12 with bit 3 set. This will disable the password protection. The message will be 500034050061AA1204cs. This message will disable the passwords. Baud rate changes will be enabled. The CCM will be set for a direct connection. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way. Note: When the passwords are disabled, all three passwords are set to all blanks (spaces).Enabling PasswordsThe AA12 and the F012 PIDs must be used in order to enable the password protection.Note: Refer to the Operation and Maintenance Manual, "Parameter Identifiers for General Usage".
Use IID 34 with a unit number of 61. Write to PID AA12 to clear bit 3. The message format will be 500034050061AA1200cs. This message will enable the following items: passwords, change of baud rate and set the CCM for direct connect. Bits 1 and 2 should be set to 1 if the last two items need to be set the other way.
In order to enable the changes, the power to the CCM must be cycled or the security level must be written to zero. The security level is written to zero by using IID 34. The message will be 500034050061F01200cs. Note: When the passwords were disabled, each character was set to a blank or space. Set the level 3 password on the CCM to something other than spaces.

Have questions with 105680-5100?





Group cross 105680-5100 ZEXEL

Mitsubishi 

105680-5100  
9 420 616 704 
NP-EP/SPG550-650B3DL 
ME755827 
AUTOM. ADVANCE MECHANISM
9 420 616 914 
NP-EP/SPG550-650B3DL 
ME755904 
AUTOM. ADVANCE MECHANISM

Hino 

9 420 616 684 
NP-EP/SPG550-800B1.5DL 
225004500A 
AUTOM. ADVANCE MECHANISM
Back to top