Information autom. advance mechanism
BOSCH
9 420 616 710
9420616710
ZEXEL
105680-5092
1056805092
MITSUBISHI
ME756180
me756180

Rating:
Scheme ###:
1. | [1] | 156800-5720 | TIMING-DEVICE HOUSING |
2. | [1] | 156801-7000 | FLANGE BUSHING |
3. | [2] | 156723-0300 | ECCENTRIC DISC |
3. | [2] | 156723-0300 | ECCENTRIC DISC |
4. | [2] | 156723-0400 | ECCENTRIC DISC |
4. | [2] | 156723-0400 | ECCENTRIC DISC |
5. | [1] | 156898-5920 | FLYWEIGHT ASSEMBLY |
5/1. | [2] | 156803-0120 | FLYWEIGHT |
5/1. | [2] | 156803-0120 | FLYWEIGHT |
5/2. | [4] | 156877-0500 | SLOTTED WASHER |
5/2. | [4] | 156877-0500 | SLOTTED WASHER |
5/3. | [4] | 156807-1300 | SLOTTED WASHER |
5/3. | [4] | 156807-1300 | SLOTTED WASHER |
5/4. | [4] | 156807-1200 | SLOTTED WASHER |
5/4. | [4] | 156807-1200 | SLOTTED WASHER |
5/5. | [4] | 156893-6200 | COMPRESSION SPRING |
5/5. | [4] | 156893-6200 | COMPRESSION SPRING |
5/6. | [4] | 156893-6300 | COMPRESSION SPRING |
5/6. | [4] | 156893-6300 | COMPRESSION SPRING |
5/7. | [4] | 156729-0500 | LOCKING WASHER |
5/7. | [4] | 156729-0500 | LOCKING WASHER |
5/8. | [2] | 156806-2320 | PIN |
5/9/1. | [0] | 156728-0800 | SHIM D19&15T0.1 |
5/9/1. | [0] | 156728-0900 | SHIM D19&15T0.3 |
5/9/1. | [0] | 156728-1000 | SHIM D19&15T0.5 |
5/9/1. | [0] | 156728-1000 | SHIM D19&15T0.5 |
5/9/1. | [0] | 156728-1100 | SHIM D19&15T1.0 |
5/9/1. | [0] | 156728-2000 | SHIM D19&15T0.4 |
5/9/1. | [0] | 156728-2100 | SHIM D19&15T0.7 |
5/9/1. | [0] | 156728-2400 | SHIM |
5/9/1. | [0] | 156728-2500 | SHIM |
5/9/1. | [0] | 156728-2600 | SHIM |
5/10/1. | [0] | 156728-1200 | SHIM D14&10.6T0.1 |
5/10/1. | [0] | 156728-1200 | SHIM D14&10.6T0.1 |
5/10/1. | [0] | 156728-1300 | SHIM D14&10.6T0.3 |
5/10/1. | [0] | 156728-1400 | SHIM D14&10.6T0.5 |
5/10/1. | [0] | 156728-1500 | SHIM D14&10.6T1.0 |
5/10/1. | [0] | 156728-2200 | SHIM D14&10.6T0.4 |
5/10/1. | [0] | 156728-2300 | SHIM D14&10.6T0.7 |
5/10/1. | [0] | 156728-2700 | SHIM |
5/10/1. | [0] | 156728-2800 | SHIM |
5/10/1. | [0] | 156728-2900 | SHIM |
13. | [1] | 156809-1520 | COVER |
13/2. | [1] | 139648-0300 | PACKING RING |
13/3. | [1] | 156315-0200 | O-RING |
30. | [1] | 156729-1400 | LOCKING WASHER |
31. | [1] | 131325-1800 | UNION NUT |
33. | [1] | 029331-0190 | GASKET D14&10.2T1 |
34. | [1] | 156316-0000 | CAPSULE |
35. | [1] | 156314-0600 | CAP |
36. | [1] | 156319-0200 | GASKET |
37. | [1] | 156914-4300 | PLATE |
38. | [2] | 020118-1840 | BLEEDER SCREW |
39. | [2] | 014020-8140 | PLAIN WASHER D16&8.5T1.2 |
40. | [1] | 479771-9222 | PULSE GENERATOR |
41. | [1] | 139316-0000 | PLAIN WASHER D25&16.5T5 |
Cross reference number
Zexel num
Bosch num
Firm num
Name
105680-5092
ME756180 MITSUBISHI
AUTOM. ADVANCE MECHANISM
K 14KL AUTOMATIC TIMER TIMER SPG TIMER
K 14KL AUTOMATIC TIMER TIMER SPG TIMER
Information:
Table 9
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $01     CCM is the sending module    
3     $25     IID 25    
4     $07     Number of bytes    
5     $58     GSC number 1    
6, 7     $00 $82     PID $0082 GSC Fault Log Codes, Status, And Number of occurrences    
8, 9     $00 $BE     CID 190 (engine speed sensor fault)    
10     $C3     Count included, inactive fault, logged fault, standard FMI (3)    
11     $04     Occurrence count of 4    
12     $24     Checksum    
IID 00 is used to request additional information on a fault 500000070058008300BEC34DIID 00 - Special parameter Command
Table 10
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $01     CCM is the sending module    
3     $00     IID 00    
4     $07     Number of bytes    
5     $00     Reply in ASCII format    
6     $58     GSC number 1    
7, 8     $00 $83     PID $0083 GSC Fault Log Request For Additional Data    
9, 10, 11     $00 $BE $C3     More information requested on CID 190 FMI 3    
12     $4D     Checksum    
IID 25 will contain the reply as PID $0084 5001250B58008400BEC303000C001102IID 25 - Single Parameter Read Response
Table 11
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $01     CCM is the sending module    
3     $25     IID 25    
4     $0B     Number of bytes    
5     $58     GSC number 1    
6, 7     $00 $84     PID $0084 GSC Fault Log Response For Additional Data    
8, 9     $00 $BE     CID 190    
10     $C3     More information on FMI 3    
11     $03     Three occurrences of this fault    
12, 13     $00 $0C     First occurrence at 12 hours    
14, 15     $00 $11     Last occurrence at 17 hours    
16     $02     Checksum    Monitoring Generator Phase
The following example shows how to select which generator phase the GSC monitors.
Use IID 34 to write the parameters of PID $F0B0: 500034050048F0B0007FIID 34 - Single Parameter Write Request
Table 12
Byte(s)    Byte Contents    Detailed Description    
1     $50     Indicates M5X protocol    
2     $00     User's PC is the sending module    
3     $34     IID 34    
4     $05     Number of bytes    
5     $00     Reply in ASCII format    
6     $58     GSC number 1    
7, 8     $F0 $B0     PID $F0B0 Generator Phase Select    
9     $00     Phase A-B Voltage, Phase A Current    
10     $7F     Checksum    
IID 35 is the response from the CCM: 5001350458F0B0007EIID 35 - Single Parameter Write Response
Table