Information autom. advance mechanism
BOSCH
9 420 615 592
9420615592
ZEXEL
105676-0260
1056760260
MITSUBISHI
ME716966
me716966

Rating:
Scheme ###:
1. | [1] | 156700-0100 | FLANGE BUSHING |
2. | [1] | 156710-2620 | FLYWEIGHT ASSEMBLY |
2/1. | [2] | 156702-9220 | FLYWEIGHT |
2/2. | [4] | 156707-0100 | SLOTTED WASHER |
2/2. | [4] | 156707-0100 | SLOTTED WASHER |
2/3. | [4] | 156707-0000 | SLOTTED WASHER |
2/3. | [4] | 156707-0000 | SLOTTED WASHER |
2/4. | [4] | 156704-4900 | COMPRESSION SPRING |
2/4. | [4] | 156704-4900 | COMPRESSION SPRING |
2/5. | [4] | 156709-0200 | LOCKING WASHER |
2/5. | [4] | 156709-0200 | LOCKING WASHER |
2/6/1. | [0] | 156708-3600 | SHIM D15.5&11.5T0.1 |
2/6/1. | [0] | 156708-3700 | SHIM D15.5&11.5T0.2 |
2/6/1. | [0] | 156708-3800 | SHIM D15.5&11.5T0.3 |
2/6/1. | [0] | 156708-3900 | SHIM D15.5&11.5T0.4 |
2/6/1. | [0] | 156708-4000 | SHIM D15.5&11.5T0.5 |
2/6/1. | [0] | 156708-4100 | SHIM D15.5&11.5T0.6 |
2/6/1. | [0] | 156708-4200 | SHIM D15.5&11.5T0.7 |
2/6/1. | [0] | 156708-4200 | SHIM D15.5&11.5T0.7 |
2/6/1. | [0] | 156708-4300 | SHIM D15.5&11.5T0.8 |
2/6/1. | [0] | 156708-4400 | SHIM D15.5&11.5T0.9 |
2/6/1. | [0] | 156708-4500 | SHIM D15.5&11.5T1.0 |
2/7. | [2] | 156706-0000 | PIN |
8. | [2] | 156703-0500 | ECCENTRIC DISC |
8. | [2] | 156703-0500 | ECCENTRIC DISC |
9. | [2] | 156703-0600 | ECCENTRIC DISC |
9. | [2] | 156703-0600 | ECCENTRIC DISC |
11. | [1] | 156701-0120 | FLANGE BUSHING |
12/1. | [0] | 156708-2200 | SHIM D46&36.1T0.1 |
12/1. | [0] | 156708-2300 | SHIM D46&36.1T0.12 |
12/1. | [0] | 156708-2400 | SHIM D46&36.1T0.14 |
12/1. | [0] | 156708-2500 | SHIM D46&36.1T0.16 |
12/1. | [0] | 156708-2600 | SHIM D46&36.1T0.18 |
12/1. | [0] | 156708-2700 | SHIM D46&36.1T0.9 |
12/1. | [0] | 156708-2800 | SHIM D46&36.1T1.10 |
12/1. | [0] | 156708-2900 | SHIM D46&36.1T1.3 |
12/1. | [0] | 156708-3000 | SHIM D46&36.1T1.5 |
12/1. | [0] | 156708-3100 | SHIM D46&36.1T1.7 |
13/1. | [0] | 156708-2200 | SHIM D46&36.1T0.1 |
13/1. | [0] | 156708-2300 | SHIM D46&36.1T0.12 |
13/1. | [0] | 156708-2400 | SHIM D46&36.1T0.14 |
13/1. | [0] | 156708-2500 | SHIM D46&36.1T0.16 |
13/1. | [0] | 156708-2600 | SHIM D46&36.1T0.18 |
13/1. | [0] | 156708-2700 | SHIM D46&36.1T0.9 |
13/1. | [0] | 156708-2800 | SHIM D46&36.1T1.10 |
13/1. | [0] | 156708-2900 | SHIM D46&36.1T1.3 |
13/1. | [0] | 156708-3000 | SHIM D46&36.1T1.5 |
13/1. | [0] | 156708-3100 | SHIM D46&36.1T1.7 |
16. | [1] | 016020-3620 | LOCKING WASHER |
17. | [1] | 156709-1000 | LOCKING WASHER |
18. | [1] | 131325-3201 | UNION NUT |
19. | [1] | 156708-2100 | PLATE |
20. | [1] | 016020-3620 | LOCKING WASHER |
21. | [1] | 156221-0200 | TOOTHED GEAR |
22. | [6] | 139006-5600 | BLEEDER SCREW |
Include in #1:
101491-1200
as AUTOM. ADVANCE MECHANIS
Cross reference number
Zexel num
Bosch num
Firm num
Name
105676-0260
ME716966 MITSUBISHI
AUTOM. ADVANCE MECHANISM
K 14KJ AUTOMATIC TIMER TIMER SCDM TIMER
K 14KJ AUTOMATIC TIMER TIMER SCDM TIMER
Information:
Introduction
The problem that is identified below does not have a known permanent solution. Until a known permanent solution is known, use the solution that is identified below.Problem
Multiple dealers have found that the "ARD Nozzle Heater Circuit Test" in Cat ET does not work after flashing to PROD 5 engine software. An error message is returned that says calibration unsuccessful when the start button is pressed. Refer to the Illustration below.
Illustration 1 g02839458
Illustration 2 g02839481
Solution
The "ARD Nozzle Heater Circuit Test" is still functional despite the error being shown. An engine software solution for this issue is in process and should be released soon.The test should be working while the calibration error is present as long as the appropriate conditions are met to run the test. Once finished troubleshooting, the technician should select "Finish" to end the circuit test.
The problem that is identified below does not have a known permanent solution. Until a known permanent solution is known, use the solution that is identified below.Problem
Multiple dealers have found that the "ARD Nozzle Heater Circuit Test" in Cat ET does not work after flashing to PROD 5 engine software. An error message is returned that says calibration unsuccessful when the start button is pressed. Refer to the Illustration below.
Illustration 1 g02839458
Illustration 2 g02839481
Solution
The "ARD Nozzle Heater Circuit Test" is still functional despite the error being shown. An engine software solution for this issue is in process and should be released soon.The test should be working while the calibration error is present as long as the appropriate conditions are met to run the test. Once finished troubleshooting, the technician should select "Finish" to end the circuit test.