105612-1180 ZEXEL 9 420 616 346 BOSCH AUTOM. ADVANCE MECHANISM 9420616346 1056121180 6072140340


 

Information autom. advance mechanism

BOSCH 9 420 616 346 9420616346
ZEXEL 105612-1180 1056121180
HINO 6072140340 6072140340
105612-1180 AUTOM. ADVANCE MECHANISM
Rating:
42
Buy AUTOM. ADVANCE MECHANISM 105612-1180 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 156132-4620 FLYWEIGHT ASSEMBLY
2. [2] 156108-0900 FLYWEIGHT
3/1. [0] 029310-9010 SHIM D19.6&9T0.5
3/1. [0] 029310-9020 SHIM D19.6&9T1
3/1. [0] 029310-9030 SHIM D19.6&9T0.1
3/1. [0] 029310-9040 SHIM D19.6&9T0.2
3/1. [0] 029310-9050 PLAIN WASHER D19.6&9T1.5
3/1. [0] 139409-0000 SHIM D19.6&9.0T0.15
4. [2] 156104-5700 COMPRESSION SPRING
11. [1] 156130-2320 FLANGE BUSHING
12. [1] 029622-8010 PACKING RING
13. [1] 156117-0100 O-RING
14. [1] 156114-1400 CASE
15. [1] 156116-2220 PACKING RING
16. [2] 026508-1240 GASKET D11.9&8.2T1
17. [2] 156115-0100 CAPSULE
18. [1] 014111-2420 LOCKING WASHER
19. [1] 131325-0200 UNION NUT

Include in #1:

101693-2560 as AUTOM. ADVANCE MECHANIS

Cross reference number

Zexel num
Bosch num
Firm num
Name
105612-1180 
9 420 616 346 
NP-EP/SA300-950A5*5RN149 
6072140340  HINO
AUTOM. ADVANCE MECHANISM
K 14KC AUTOMATIC TIMER TIMER SA TIMER
105612-1180 
9 420 616 346 
NP-EP/SA300-950A5*5RN149 
225001570A  HINO
AUTOM. ADVANCE MECHANISM
A K 14KC AUTOMATIC TIMER TIMER SA TIMER




Information:

3T1888 Alternator 24V 50A (Delco-Remy Number 117248)
3T1888 Alternator1. Remove the covers from the end of the alternator to get access to the voltage regulator.
Delco-Remy Regulator Adjustment
(1) Potentiometer adjustment screw. (2) Transistor pins.2. Remove the rubber from the potentiometer so that the small screw can be seen.3. Connect a voltmeter across the batteries to measure the regulation of the voltage. The batteries must have a good charge for this measurement.4. Operate the alternator at medium speed for 30 seconds and take a measurement of the voltage. The voltage must be 27.5 1.0 volts. Turn the small screw counterclockwise to get less voltage output and clockwise to get more voltage output.5. After adjustment has been made, put a think layer of 3S6252 Silicone Rubber Sealant on the adjustment screw and install the covers. Make sure the location of the wires to the voltage regulator is not over the transistor pins. The transistor pins could make holes in the insulation for the wires and cause a short circuit.7N9720 Alternator 24V 35A (Bosch Number 0-122-469-001); 9G9538 Alternator 24V 50A (Bosch Number 0-122-469-002)
7N9720 AlternatorThe solid state regulator used with the Bosch Alternator is totally enclosed and non-adjustable. If the rate of charge is not correct a replacement of the regulator is necessary.9G4574 24V 35A (Nippondenso Number 100211-0860); 6T7223 24V 50A (Nippondenso Number 100211-0890)
9G4574 AlternatorNo adjustment can be made to change the rate of charge on the alternator regulator. If rate of charge is not correct, a replacement of the regulator is necessary.Starting System
Use the multimeter in the DCV range to find starting system components which do not function.Move the start control switch to activate the starter solenoid. Starter solenoid operation can be heard as the pinion of the starter motor is engaged with the ring gear on the engine flywheel.If the solenoid for the starter motor will not operate, it is possible that the current from the battery did not get to the solenoid. Fasten one lead of the multimeter to the connection (terminal) for the battery cable on the solenoid. Put the other lead to a good ground. A zero reading is an indication that there is a broken circuit from the battery. More testing is necessary when there is a voltage reading on the multimeter.The solenoid operation also closes the electric circuit to the motor. Connect one lead of the multimeter to the solenoid connection (terminal) that is fastened to the motor. Put the other lead to a good ground. Activate the starter solenoid and look at the multimeter. A reading of battery voltage shows the problem is in the motor. The motor must be removed for further testing. A zero reading on the multimeter shows that the solenoid contacts do not close. This is an indication of the need for repair to the solenoid or an adjustment to be made to the starter pinion clearance.Make a test with one multimeter lead fastened to the connection (terminal) for the small wire at the solenoid and the other lead to the

Have questions with 105612-1180?





Group cross 105612-1180 ZEXEL

Hino 

9 420 616 345 
NP-EP/SA500-1150A2*5RN141 
6072140140 
AUTOM. ADVANCE MECHANISM
9 420 616 345 
NP-EP/SA500-1150A2*5RN141 
225001560A 
AUTOM. ADVANCE MECHANISM
 
225001530A 

Mitsubishi 

9 420 615 654 
NP-EP/SA500-1250A6.5RN143 
3116144600 
AUTOM. ADVANCE MECHANISM

Hino 

9 420 616 736 
NP-EP/SA500-1150A2*5RN146 
225001540A 
AUTOM. ADVANCE MECHANISM
105612-1180  
9 420 616 346 
NP-EP/SA300-950A5*5RN149 
6072140340 
AUTOM. ADVANCE MECHANISM
105612-1180  
9 420 616 346 
NP-EP/SA300-950A5*5RN149 
225001570A 