159601-7720 ZEXEL F 019 Z2E 553 BOSCH ADJUSTING DEVICE f019z2e553 1596017720


 

Information adjusting device

BOSCH F 019 Z2E 553 f019z2e553
ZEXEL 159601-7720 1596017720
159601-7720 ADJUSTING DEVICE
Rating:
37
Buy ADJUSTING DEVICE 159601-7720 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 159598-5020 DIAPHRAGM HOUSING
2. [6] 159596-2800 BLEEDER SCREW
3. [1] 159610-1400 SEAL RING
5. [1] 131420-0400 BLEEDER SCREW
6. [1] 026506-1040 GASKET D9.9&6.2T1
8. [2] 029341-4130 GASKET D20&13.8T2*
9. [1] 029731-4680 EYE BOLT
15. [1] 159605-6620 ACTUATOR
16. [1] 159610-1300 SEAL RING
17. [4] 010206-3040 HEX-SOCKET-HEAD CAP SCREW M6P1L30
17. [4] 010206-3040 HEX-SOCKET-HEAD CAP SCREW M6P1L30
18. [1] 139306-0400 PLAIN WASHER
19. [4] 029320-6010 LOCKING WASHER
19. [4] 029320-6010 LOCKING WASHER
20. [3] 159595-5700 PLAIN WASHER
800S. [1] 159595-8801 COVER
801S. [1] 159610-1200 SEAL RING
802S. [4] 010206-3040 HEX-SOCKET-HEAD CAP SCREW M6P1L30
803S. [4] 029320-6010 LOCKING WASHER
804S. [1] 159911-5900 PLUG HOUSING

Cross reference number

Zexel num
Bosch num
Firm num
Name
159601-7720 
F 019 Z2E 553 
   
ADJUSTING DEVICE
K 74HA ACTUATOR ASSY FUN ACT




Information:

If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).E1156(1) - Filter intake pressure greater than 10 kPa (1.50 psi) for more than 10 seconds. Refer to Table14 for troubleshooting.E1156(2) - Filter intake pressure greater than 15 kPa (2.25 psi) for more than 10 seconds. Refer to Table14 for troubleshooting.A faulty sensor may cause this diagnostic code. First determine that the sensor is not faulty.
Table 14
Troubleshooting Test Steps Values Results
1. Check for Associated Diagnostic Codes.
A. Establish communication between the Cat® Electronic Technician (ET) and the engine Electronic Control Module (ECM).
B. Troubleshoot any associated diagnostic codes that are present before continuing with this procedure.
Associated Diagnostic Codes
Result: An associated diagnostic code is not present.
Proceed to Test Step 2.
Result: An associated diagnostic code is active or logged.
1. Troubleshoot the associated diagnostic code before continuing with this procedure.
2. Service Maintenance.
A. Determine the most recent cleaning of the Wall Flow Filter (WFF).
Cleaning Interval
Result: The WFF was cleaned within the last 1000 hours.
Proceed to Test Step 3.
Result: The WFF was not cleaned within the last 1000 hours.
Proceed to Test Step 4.
3. Check for Contamination.
A. Reset all active codes and clear all logged codes.
B. Remove the WFF.
C. Check for contamination on the face of the WFF.
Contamination
Result: There is no sign of oil, fuel, or coolant on the WFF.
Proceed to Test Step 4.
Result: There is oil, fuel, or coolant on the WFF.
1. Diagnose the cause of the contamination.
2. The engine must be run with no load at 1400 rpm for at least 15 minutes, or until there is no white smoke.
3. If white smoke continues, or if the diagnostic code remains active, proceed to Test Step 5.
4. Clean the WFF.
A. Clean the WFF. Refer to "Wall Flow Diesel Particulate Filter - Clean".
B. Reset all active codes and clear all logged codes.
Clean was successful
Result: Cleaning the WFF was successful.
Return the machine to service.
Result: Cleaning the WFF was not successful.
1. Troubleshoot any diagnostic codes that are present, if no codes are present, proceed to Test Step 6.
5. Replace the WFF.
Replacement was successful
Result: Replacing the WFF was successful.
Return the machine to service.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).Exhaust Temperature Is High
Certain operating conditions may cause the exhaust temperature to increase to a level that may damage engine components.Probable Causes
Boost Leak
Engine operating conditions
High altitude
Obstructed aftercooler
Table 15
Troubleshooting Test Steps Values Results
1. Check for Boost Leakage.
A. Apply a light load to the engine and check for boost leakage.
Boost Leaks
Result: Boost leakage was found.
Repair: Repair the leaks. Return the machine to service.
Result: Boost leakage was not found.
Proceed to Test Step 2.
2. Check the Engine Operating Conditions.
A. Check the histogram to determine if the high exhaust temperature was due to normal operation.
When possible, interview the operator. Determine if the engine is being operated under heavy load. Ensure that the engine is being operated at the

Have questions with 159601-7720?