159600-8621 ZEXEL 9 421 620 897 BOSCH ADJUSTING DEVICE 9421620897 1596008621 me748749


 

Information adjusting device

BOSCH 9 421 620 897 9421620897
ZEXEL 159600-8621 1596008621
MITSUBISHI ME748749 me748749
159600-8621 ADJUSTING DEVICE
Rating:
63
Buy ADJUSTING DEVICE 159600-8621 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 159598-2623 DIAPHRAGM HOUSING
2. [4] 159596-2800 BLEEDER SCREW
3. [1] 159610-1700 SEAL RING
5. [1] 131420-0400 BLEEDER SCREW
6. [1] 026506-1040 GASKET D9.9&6.2T1
8. [2] 029341-4130 GASKET D20&13.8T2*
9. [1] 139814-0900 EYE BOLT
15. [1] 159604-9022 ACTUATOR
16. [1] 159610-1500 SEAL RING
17. [4] 010206-3040 HEX-SOCKET-HEAD CAP SCREW M6P1L30
17. [4] 010206-3040 HEX-SOCKET-HEAD CAP SCREW M6P1L30
18. [4] 029320-6010 LOCKING WASHER
18. [4] 029320-6010 LOCKING WASHER
19. [1] 139306-0400 PLAIN WASHER
20. [3] 159595-5700 PLAIN WASHER
30. [1] 159597-6700 BRACKET
31. [2] 020106-1440 BLEEDER SCREW M6P1.0L14
32. [2] 159911-1100 CLAMPING BAND
32. [2] 159911-1100 CLAMPING BAND
800S. [1] 159595-9201 COVER
801S. [1] 159610-1600 SEAL RING
802S. [4] 010206-3040 HEX-SOCKET-HEAD CAP SCREW M6P1L30
803S. [4] 029320-6010 LOCKING WASHER
804S. [1] 159910-6800 PLUG HOUSING

Include in #1:

Cross reference number

Zexel num
Bosch num
Firm num
Name
159600-8621 
9 421 620 897 
ME748749  MITSUBISHI
ADJUSTING DEVICE
K 74HA ACTUATOR ASSY FUN ACT




Information:

I/O Error Codes for the SLC 500 Only
The characters "xx" in table 5 represent the slot. The slot is the module that is causing the error.1F is indicated. There is a fault. The exact slot could not be determined. Check the grounding of the chassis.
Table 5
Slot    xx    
0     00    
1     01    
2     02    
3     03    
4     04    
5     05    
6     06    
7     07    
8     08    
9     09    
10     0A    
11     0B    
12     0C    
13     0D    
14     0E    
15     0F    
16     10    Major faults can be one of the following types:Non-User (1) - The fault routine does not execute.Non-Recoverable (2) - The fault routine executes for 1 pass.Recoverable (3) - The fault may clear S:1/13 in order to resume operation.
Table 6
I/O Error Codes    
Code    Type    Description    
xx39     3     Invalid string length was detected in a string line    
xx50     3     A rack data error is detected (recoverable only if user disables slot xx in user fault routine    
xx51