152118-1600 ZEXEL 9 441 610 234 BOSCH ADAPTOR 9441610234 1521181600 1157590610


 

Information adaptor

BOSCH 9 441 610 234 9441610234
ZEXEL 152118-1600 1521181600
ISUZU 1157590610 1157590610
152118-1600 ADAPTOR
Rating:
20
Buy ADAPTOR 152118-1600 zexel genuine, new aftermarket engine parts with delivery

Cross reference number

Zexel num
Bosch num
Firm num
Name
152118-1600 
9 441 610 234 
1157590610  ISUZU
ADAPTOR
C 14GD ADAPTER F/P
152118-1600 
9 441 610 234 
1157590520  ISUZU
ADAPTOR
A C 14GD ADAPTER F/P
152118-1600 
9 441 610 234 
ME740162  MITSUBISHI
ADAPTOR
C 14GD ADAPTER F/P
152118-1600 
9 441 610 234 
16658Z9002  NISSAN-DIESEL
ADAPTOR
C 14GD ADAPTER F/P




Information:


Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
2301A Electric Governor Control
The 2301A Electric Governor Control activates all of the components that are in the electric protection system. The components are activated in the same manner when the nonelectric governor is used. One difference exists in the main circuit. The fuel shutoff solenoid (FSOS) (line 43) is not used.When the electric governor control is used, the engine must run in a normal condition in order for the electric circuit to operate in the manner that is described below.
Current flows from the terminals (TS-28) (line 43) and (TS-31) (line 44), which are located on the terminal strip in the junction box.
Current from terminals (TS-28) (line 43) and (TS-31) (line 44) flows through the preregulator (PR) (line 48) or the fuse (F4) to the electric governor control.
When the engine flywheel is rotating, the current also flows through the electric governor actuator (EGA) (line 52). When a fault in the system causes the current to energize the slave relay (SR1), the following events occur in the electric circuit in order to stop the engine.
The slave relay (SR1) opens across the contacts (SR1-30) and (SR1-87a) (line 45). The relay closes across the contacts (SR1-30) and (SR1-87) (line 43).
When the circuit opens across contacts (SR1-30) and (SR1-87a), the current is stopped to the electric governor control.
Current to the electric governor actuator (EGA) is also stopped.
The mechanical spring load in the electric governor actuator (EGA) will now move the fuel control rod in order to stop fuel flow to the engine. Note: With the exception of the differences that are described in this section of the manual, all of the fault circuits in the electric protection system are identical for the 2301A Electric Governor Control and for the nonelectric governor control.
Illustration 3 g00292636
Junction Box Wiring for ETR protection

Have questions with 152118-1600?





Group cross 152118-1600 ZEXEL

Isuzu 

152118-1600  
9 441 610 234 
1157590610 
ADAPTOR
152118-1600  
9 441 610 234 
1157590520 
ADAPTOR

Mitsubishi 

152118-1600  
9 441 610 234 
ME740162 
ADAPTOR

Nissan-Diesel 

152118-1600  
9 441 610 234 
16658Z9002 
ADAPTOR
Back to top