105952-1370 ZEXEL 9 420 610 809 BOSCH ACTUATOR 9420610809 1059521370


 

Information actuator

BOSCH 9 420 610 809 9420610809
ZEXEL 105952-1370 1059521370
105952-1370 ACTUATOR
Rating:
35
Buy ACTUATOR 105952-1370 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 159560-0100 GOVERNOR HOUSING
2. [8] 139006-4100 BLEEDER SCREW
3. [1] 029621-7050 PACKING RING
4. [1] 159564-0000 COILED SPRING
5. [1] 159564-4000 SLOTTED WASHER
6. [1] 159564-4100 SLOTTED WASHER
7. [1] 159564-7321 CONNECTOR
8. [1] 020105-1240 BLEEDER SCREW M5P0.8L12
9. [1] 159564-0501 PLATE
9B. [1] 159564-6500 PLATE
9C. [1] 159584-5200 PLATE
10. [1] 020105-1240 BLEEDER SCREW M5P0.8L12
11. [1] 159569-0521 ACTUATOR
12. [2] 020106-4040 BLEEDER SCREW
13. [1] 159561-0400 GOVERNOR COVER
14. [4] 010006-7040 BLEEDER SCREW M6P1L70
15. [2] 010006-5540 BLEEDER SCREW M6P1L55 4T
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
17. [1] 154371-5600 GASKET
18. [1] 154390-0400 GASKET
19. [1] 154390-0500 GASKET
20. [1] 153021-3120 STOPPING DEVICE
21. [1] 026524-3040 GASKET
22. [1] 029731-4680 EYE BOLT
23. [2] 029341-4130 GASKET D20&13.8T2*
27. [2] 139006-1300 BLEEDER SCREW M6P1L76
80. [1] 159584-0000 TOOTHED GEAR
81. [1] 014111-2420 LOCKING WASHER
82. [1] 013031-2120 UNION NUT
83. [1] 025803-1310 WOODRUFF KEY
900S. [1] 025803-1310 WOODRUFF KEY
901S. [1] 025803-1610 WOODRUFF KEY

Include in #1:

106675-4191 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105952-1370 
105952-2700 
9 420 610 809 
   
ACTUATOR
* K 14JD GOV




Information:

You must read and understand the warnings and instructions contained in the Safety section of this manual before performing any operation or maintenance procedures.Before proceeding with Every 1000 Hour maintenance, perform all previous maintenance interval requirements.Engine Protection Devices
Inspect for Proper Operation
Refer to the Service Manual for the procedure. All engine protective devices must be checked and maintained to provide the engine with proper protection if a component malfunction or failure should occur. Check all engine protective devices. Never use the Emergency Shutdown controls for a normal stopping procedure.SR4 Generator and Control Panel (If Equipped)
SR4 Generator
Before working inside the generator, make sure that the starting motor can not be activated by any automatic or manual signal.When the engine-generator is operating, voltages up to 600V are present in these areas near or on the regulator: 1. the regulator terminal strip2. the excitation transformer terminal strip (self-excited generator only)Do not short these terminals to ground with any part of the body or any conductive material. Loss of life or injury could result from electrical shock or injury from molten metal.
Electronic components in the regulator can be damaged during generator operation if contact is made between the part and ground.
Clean/Inspect Voltage Regulator
If moisture is allowed to remain in contact with an electrical winding, some of the moisture will eventually be absorbed. This will lower the resistance of the winding insulation. The insulation used on the windings of Caterpillar generators is moisture resistant, but constant exposure to moisture will gradually lower the insulation's resistance.Dirt can make the problem worse because it can hold the moisture in contact with the insulation. Salt (from coastal location sea air) can also make the problem much worse. This is because salt tends to absorb moisture from the air. When the salt and moisture combine, they make a good electrical conductor.* Clean the voltage regulator and generator of dirt and debris. Use a brush to loosen accumulations of dirt and a vacuum system for removal. Use of compressed air is not recommended, because of moisture present in the form of condensate.Carbon tracking on insulators can be caused by dirt or loose connections. These carbon paths must be cleaned or the insulators replaced. Failure to correct a carbon tracking problem will eventually result in a short in the electrical circuit.* Visually check for loose or broken wires and connections. Check the wires and connections on the regulator assembly. Check all wires and connections in the generator. Make any necessary repairs to the wiring as required.Visually inspect the generator and control panel. Check for loose, broken, or damaged wiring or components. The inspection only takes a few minutes and could avert a potential problem that could cause your generator set to fail.Operational Checks
Start the engine. Use the starting procedure found in the SR4 Generators and Control Panels Operation and Maintenance Manual, SEBU6150.The following operational checks include: * generator operation and engine starting* lubricating and fuel systems* overall operationThe checks should take no longer than five minutes to complete. A

Have questions with 105952-1370?





Group cross 105952-1370 ZEXEL

Nissan-Diesel 

9 420 610 884 
1910697501 
ACTUATOR
9 420 612 834 
1910697006 
ACTUATOR
9 420 612 835 
1910697502 
ACTUATOR
9 420 611 880 
1910697007 
ACTUATOR
9 420 612 193 
 
ACTUATOR

Nissan-Diesel 

9 420 610 885 
1910697008 
ACTUATOR
F 019 Z5E 980 
1910695504 
ACTUATOR
105952-1370  

105952-2700 
9 420 610 809 
 
ACTUATOR
9 420 612 483 
 
ACTUATOR

Mitsubishi 

F 019 Z5E 981 
ME740039 
ACTUATOR
Back to top