105952-1262 ZEXEL F 019 Z9E 114 BOSCH ACTUATOR f019z9e114 1059521262 me740417


 

Information actuator

BOSCH F 019 Z9E 114 f019z9e114
ZEXEL 105952-1262 1059521262
MITSUBISHI ME740417 me740417
105952-1262 ACTUATOR
Rating:
21
Buy ACTUATOR 105952-1262 zexel genuine, new aftermarket engine parts with delivery

Scheme ###:

1. [1] 159560-1802 GOVERNOR HOUSING
2. [10] 139006-4100 BLEEDER SCREW
4. [1] 159564-0000 COILED SPRING
5. [1] 159564-4000 SLOTTED WASHER
6. [1] 159564-4100 SLOTTED WASHER
7. [1] 159564-7320 CONNECTOR
8. [1] 020105-1240 BLEEDER SCREW M5P0.8L12
9. [1] 159564-0501 PLATE
10. [1] 020105-1240 BLEEDER SCREW M5P0.8L12
11. [1] 159569-3622 ACTUATOR
12. [2] 020106-4040 BLEEDER SCREW
13. [1] 159561-0920 GOVERNOR COVER
14. [4] 010006-7040 BLEEDER SCREW M6P1L70
15. [2] 010006-5540 BLEEDER SCREW M6P1L55 4T
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
16. [8] 014110-6440 LOCKING WASHER
17. [1] 159566-4401 GASKET
18. [1] 154390-0400 GASKET
19. [1] 154390-0500 GASKET
20. [1] 154611-7020 RACK SENSOR ASSY
20/1. [1] 479775-3920 RACK SENSOR
20/2. [1] 154614-4800 JOINT CONNECTION
20/3. [1] 154614-3200 BLOCK
20/4. [1] 010234-1040 HEX-SOCKET-HEAD CAP SCREW
20/5. [1] 014110-4440 LOCKING WASHER
20/6. [1] 026524-3040 GASKET
20/7A. [0] 029310-6220 SHIM D11.5&6.5T0.10
20/7B. [0] 029310-6230 SHIM D11.5&6.5T0.20
20/7C. [0] 029310-6240 SHIM D11.5&6.5T0.25
20/7D. [0] 029310-6260 SHIM D11.5&6.4T1.00
20/7E. [0] 029310-6270 SHIM D11.5&6.4T1.20
20/7F. [0] 029310-6280 SHIM D11.5&6.4T1.50
20/8. [1] 154614-1900 UNION NUT
20/9. [1] 154614-3300 BEARING PIN
22. [1] 153556-4800 EYE BOLT
23. [2] 029331-2120 GASKET
27. [2] 139006-1300 BLEEDER SCREW M6P1L76
28. [1] 139008-1100 BLEEDER SCREW
30. [1] 159564-7900 BRACKET
32. [2] 020006-1240 BLEEDER SCREW M6P1L12 4T
80. [1] 159584-1000 TOOTHED GEAR
81. [1] 014111-2420 LOCKING WASHER
82. [1] 013031-2120 UNION NUT
83. [1] 025803-1310 WOODRUFF KEY
900S. [1] 025803-1310 WOODRUFF KEY
901S. [1] 025803-1610 WOODRUFF KEY

Include in #1:

108922-2023 as GOVERNOR

Cross reference number

Zexel num
Bosch num
Firm num
Name
105952-1262 
105952-1263 
F 019 Z9E 114 
ME740417  MITSUBISHI
ACTUATOR
* K




Information:

Proper operation and maintenance are key factors in obtaining the maximum life and economy of the engine. Following the directions in this manual will lower operating costs.The time needed for the engine to reach the normal mode of operation is usually less than the time taken for a walk-around-inspection of the engine.After the engine is started and the cold low idle operation is completed, the engine can be operated at rated speed and low power. The engine will reach normal operating temperature faster when operated at rated speed and low power demand than when idled at no load. Typically the engine should be up to operating temperature in a few minutes.Governors and Actuators
Your engine may be equipped with a:* full-range governor* Woodward PSG Governor* Woodward 1724 Actuator* Woodward 524 Actuator
PSG Actuator
1724/524 ActuatorWoodward Governors/Actuators are usually electrically operated from a control panel. The application is usually an EPG power generator set. On standby gen sets the governor may be set to operate only at Full Load Speed.Change Engine Speed
If equipped with a control panel, a RAISE/LOWER switch or a speed setting potentiometer is used to adjust the operating speed.Starting, Operating and Stopping Engines Equipped with Control Panels
For all information regarding the generator control panel used for starting, operating and stopping the engine, refer to the Engine Protection Devices Generator Set Control Panel topic in this publication or Caterpillar SR4 Generators and Control Panels, SEBU6150. Additional information and programming instructions are provided in the Service Manual for your specific control panel.Mechanical Governors (If Equipped)
Governor Control LeverYour engine may be equipped with a full-range governor. Most other manufacturers' engines have min-max type governors that only govern at high and low idle to prevent the engine from overspeeding or dying. With the min-max governor, the position of the speed lever determines the amount of fuel delivered to the engine.With the full-range governor, the position of the speed lever sets engine speed and helps hold a constant speed independent of load which makes operation easier.The governor control motor is a 24 volt motor which allows for engine speed control from a remote location through a governor RAISE/LOWER switch. This governor control switch is used with the optional EMCP II. Always increase engine speed to high idle before applying load.For information regarding initial checks and adjustments, refer to the Service Manual or contact your Caterpillar dealer.Driven Equipment Without Load
1. Move the governor control lever to half engine speed.2. Interrupted starts put excessive stress on the drive train and waste fuel. To get the driven equipment in motion, engage the clutch smoothly, with no load on the equipment. This should result in a smooth, easy start without increasing the engine speed above low idle or slipping the clutch. For generator sets, move the governor control to high idle (full load) position (1800 rpm for 60 Hz and 1500 rpm for 50 Hz).3. Apply the load and check the gauges and equipment for proper operation. Begin operating the engine at low load. After normal oil pressure

Have questions with 105952-1262?





Group cross 105952-1262 ZEXEL

Mitsubishi 

F 019 Z9E 113 
ME738661 
ACTUATOR
9 420 610 516 
ME740067 
ACTUATOR
9 420 610 516 
ME740104 
ACTUATOR
105952-1262  

105952-1263 
F 019 Z9E 114 
ME740417 
ACTUATOR
9 420 611 069 
ME740553 
ACTUATOR
Back to top