Information actuator
BOSCH
9 420 612 723
9420612723
ZEXEL
105952-1020
1059521020
ISUZU
1157507630
1157507630

Rating:
Scheme ###:
1. | [1] | 159560-0100 | GOVERNOR HOUSING |
2. | [8] | 139006-4100 | BLEEDER SCREW |
3. | [1] | 029621-7050 | PACKING RING |
4. | [1] | 159564-0000 | COILED SPRING |
5. | [1] | 159564-4000 | SLOTTED WASHER |
6. | [1] | 159564-4100 | SLOTTED WASHER |
7. | [1] | 159564-7320 | CONNECTOR |
8. | [1] | 020105-1240 | BLEEDER SCREW M5P0.8L12 |
9. | [1] | 159564-0501 | PLATE |
10. | [1] | 020105-1240 | BLEEDER SCREW M5P0.8L12 |
11. | [1] | 159567-9522 | ACTUATOR |
12. | [2] | 020106-4040 | BLEEDER SCREW |
13. | [1] | 159561-0400 | GOVERNOR COVER |
14. | [4] | 010006-7040 | BLEEDER SCREW M6P1L70 |
15. | [2] | 029010-6550 | BLEEDER SCREW |
16. | [8] | 014110-6440 | LOCKING WASHER |
16. | [8] | 014110-6440 | LOCKING WASHER |
16. | [8] | 014110-6440 | LOCKING WASHER |
17. | [1] | 154371-5600 | GASKET |
18. | [1] | 154390-0400 | GASKET |
19. | [1] | 154390-0500 | GASKET |
20. | [1] | 153021-6300 | CAP |
21. | [1] | 139524-0000 | GASKET |
22. | [1] | 159564-0800 | EYE BOLT |
23. | [2] | 139514-0000 | GASKET D19.2&14.2T1.0 |
27. | [2] | 139006-1300 | BLEEDER SCREW M6P1L76 |
80. | [1] | 159564-2500 | TOOTHED GEAR |
81. | [1] | 014111-2420 | LOCKING WASHER |
82. | [1] | 013031-2120 | UNION NUT |
83. | [1] | 025803-1610 | WOODRUFF KEY |
900S. | [1] | 025803-1310 | WOODRUFF KEY |
901S. | [1] | 025803-1610 | WOODRUFF KEY |
Cross reference number
Zexel num
Bosch num
Firm num
Name
Information:
Altitude Operation
The fuel system settings and altitude limits are stamped on the engine information plate. When an engine is moved to a higher altitude, these settings must be changed by your Caterpillar dealer in order to prevent damaging the turbocharger, and to provide maximum engine efficiency. If the engine is moved to a lower altitude than that which is stamped on the engine information plate, the engine can be operated safely; however, it will deliver less than rated horsepower, and the fuel settings should be changed by your Caterpillar dealer to obtain rated horsepower.Stopping
1. Flywheel clutch operation: Quickly pull the clutch lever to the released position. For electric set operation, see the GENERATOR SET OPERATION instructions. For Woodward Governor operation, see the topic, WOODWARD GOVERNORS, Stopping the Engine. 2. Reduce engine speed to half speed. Run for 5 minutes to cool engine.3. Reduce engine speed to low idle.4. Observe the crankcase oil level while the engine is idling. Maintain the oil level between the ADD and FULL marks on the side of the dipstick stamped, CHECK WITH ENGINE RUNNING. See the LUBRICATION AND MAINTENANCE SECTION.5. Stop the engine. After Stopping Checks And Procedures
1. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE SECTION: Fuel Tank Maintenance.2. Drain the raw water system if below freezing temperatures are expected; see: Draining Raw Water System.3. If below freezing temperatures are expected, allow the engine jacket water expansion tank to cool; then check the coolant for proper antifreeze protection. Add permanent-type antifreeze, if required.4. Repair any leaks, make major adjustments, tighten loose bolts, etc.5. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART.
SERVICE METER
The fuel system settings and altitude limits are stamped on the engine information plate. When an engine is moved to a higher altitude, these settings must be changed by your Caterpillar dealer in order to prevent damaging the turbocharger, and to provide maximum engine efficiency. If the engine is moved to a lower altitude than that which is stamped on the engine information plate, the engine can be operated safely; however, it will deliver less than rated horsepower, and the fuel settings should be changed by your Caterpillar dealer to obtain rated horsepower.Stopping
1. Flywheel clutch operation: Quickly pull the clutch lever to the released position. For electric set operation, see the GENERATOR SET OPERATION instructions. For Woodward Governor operation, see the topic, WOODWARD GOVERNORS, Stopping the Engine. 2. Reduce engine speed to half speed. Run for 5 minutes to cool engine.3. Reduce engine speed to low idle.4. Observe the crankcase oil level while the engine is idling. Maintain the oil level between the ADD and FULL marks on the side of the dipstick stamped, CHECK WITH ENGINE RUNNING. See the LUBRICATION AND MAINTENANCE SECTION.5. Stop the engine. After Stopping Checks And Procedures
1. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE SECTION: Fuel Tank Maintenance.2. Drain the raw water system if below freezing temperatures are expected; see: Draining Raw Water System.3. If below freezing temperatures are expected, allow the engine jacket water expansion tank to cool; then check the coolant for proper antifreeze protection. Add permanent-type antifreeze, if required.4. Repair any leaks, make major adjustments, tighten loose bolts, etc.5. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART.